Sign In | Join Free | My himfr.com
Home > RCD Circuit Breaker >

4 Pole RCD Circuit Breaker 415V 63A 3 Phase Circuit Breaker

Chengdu Honors Technology Co.,Ltd
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap 4 Pole RCD Circuit Breaker 415V 63A 3 Phase Circuit Breaker from wholesalers
     
    Buy cheap 4 Pole RCD Circuit Breaker 415V 63A 3 Phase Circuit Breaker from wholesalers
    • Buy cheap 4 Pole RCD Circuit Breaker 415V 63A 3 Phase Circuit Breaker from wholesalers
    • Buy cheap 4 Pole RCD Circuit Breaker 415V 63A 3 Phase Circuit Breaker from wholesalers
    • Buy cheap 4 Pole RCD Circuit Breaker 415V 63A 3 Phase Circuit Breaker from wholesalers

    4 Pole RCD Circuit Breaker 415V 63A 3 Phase Circuit Breaker

    Ask Lasest Price
    Brand Name : ANS
    Model Number : ANS-RCD-63A
    Certification : TUV,CE
    Price : USD
    Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
    Supply Ability : 1000pcs a day
    Delivery Time : 20-30days
    • Product Details
    • Company Profile

    4 Pole RCD Circuit Breaker 415V 63A 3 Phase Circuit Breaker


    40A 4 Pole 30mA Type B 10KA Residual Current RCD Circuit Breaker


    What are RCDs?

    Residual Current Devices (RCDs) are safety switching devices. They are designed to provide safety for three types of protection;

    1. Fault Protection. Any tripping current dependent on the resistance of the earth path.
    2. Additional Protection. RCDs not exceeding 30 mA tripping current.
    3. Fire Protection. A tripping current not exceeding 300 mA.

    Specification


    Type(wave form of the earth leakage sensed)B Type RCCB
    Rated current In
    63A
    Poles4P
    Rated voltage Ue
    2P 240V~,4P 415V~
    Insulation voltage Ui500V
    Rated frequency50/60Hz
    Rated residual operation current(I n)30mA
    Rated residual making and breaking capacity (I m)
    500A(In≤40A), 10In(In>40A)
    Short-circuit current Inc= I c10000A
    SCPD fuse10000
    Break time under I n≤0.1s
    Rated impulse withstand voltage(1.5/50) Uimp4000V
    Dielectric test voltage at ind.Freq. for 1min2.5kV
    Electrical life2,000 Cycles
    Mechanical life4,000 Cycles

    Installation


    Contact position indicatorYes
    Protection degreeIP20
    Ambient temperature(with daily average≤35°C)-5°C~+40°C
    Storage temperature-25°C~+70°C
    Terminal connection typeCable/Pin-type busbar/U-type busbar
    Terminal size top/bottom for cable35mm2 18-3AWG
    Terminal size top/bottom for busbar35mm2 18-3AWG
    Tightening torque2.5Nm 22In-lbs
    MountingOn DIN rail EN60715(35mm) by means of fast clip device
    Connection
    Power supply in both directions

    Tripping Current Range


    Tripping
    Lagging Angle
    I△n>0.01A
    I△n≤0.01A
    Current
    0.35I△n≤I△≤1.4I△n
    0.35I△n≤I△≤2I△n
    Range
    90°
    0.25I△n≤I△≤1.4I△n
    0.25I△n≤I△≤2I△n
    135°
    0.11I△n≤I△≤1.4I△n
    0.11I△n≤I△≤2I△n

    Detectable wave formPulsating direct current sensitiveSurge current proof
    B class
    Tripping is ensured for sinusoidal AC residual currents pulsed DC residual currents,alternating residual sinusoidal currents up to 1000Hz,pulsating direct residual currents and for smooth direct residual currents,whether applied suddenly or increasing slowly.
    RCD.jpg
    They react to AC and pulsating DC fault current which reach 0 or almost 0 within one time period of the mains frequency.
    rccb.jpg
    RCCB’s surge capacity.
    Not tripping at standardized 8/20 υs surge-current waves acc.to VDE 0432 Part 2 with surge current values of up to 250A.

    Circuit Diagram

    What are the effects of DC residual fault current on RCDs?
    it might be worth thinking about some older models of earth fault loop impedance testers, which could cause the RCD to operate unintentionally. To prevent this, some types of earth fault loop impedance testers imposed a DC current on the AC test current. This DC current saturated the magnetic core of the RCD preventing it from tripping under the test condition.


    Where equipment produces an element of residual DC, for example, variable-speed drives is connected to the electrical installation, the DC component can saturate the magnetic core and effectively blind or locks the RCD. This is known as ‘blinding’ and could either prevent the RCD from operating or reduce the sensitivity resulting in a dangerous situation.


    Application


    Construction sites

    Agricultural and horticultural premises

    Conducting locations with restricted movement

    Caravan and camping parks

    Exhibition shows and stands

    Outdoor lighting

    Marinas

    Medical locations

    Solar Photovoltaic system power supplies

    Mobile or transportable units

    Electric vehicle charging installations

    Temporary installations for structures, amusement devices and booths at fairgrounds, amusement parks and circuses, and

    Floor and ceiling heating systems.


    Certification:TUV


    Quality 4 Pole RCD Circuit Breaker 415V 63A 3 Phase Circuit Breaker for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Chengdu Honors Technology Co.,Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)